Our Services

Nationwide Fire Sprinkler Systems

At ReCom Fire Protection, we offer a complete range of fire sprinkler services — from initial design and supply through to installation, project management and ongoing maintenance.

Our commitment is to deliver safe, compliant systems in accordance with all applicable regulations and standards, with a focus on quality, reliability, and clear client communication throughout every stage of a project.

Tailored to suit a wide range of residential and commercial environments.

We design and install systems that comply with the latest fire safety standards, whether for new builds, refurbishments or retrofit projects.

Dry Risers

Dry risers are required in buildings where the topmost floor is more than 18 metres above fire service access level, or where any floor is more than 10 metres below it, as outlined in Approved Document B (Fire Safety).

Our dry riser systems are designed and installed in line with BS 9990 and include:

  • A ground-level breaching inlet with instantaneous couplings

  • Outlet valves at every level, including the ground floor

  • Valves located in fire-resistant, ventilated areas for safe hose connection

  • Instantaneous couplings for quick and secure hose access

  • Valve security via chain and padlock, or integration with monitoring systems

During construction, a dry riser should be installed once any floor reaches 11 metres above access level where combustible materials are stored. For buildings exceeding 50 metres, a wet riser is required.

Book a Free Consultation

Wet Risers

Wet risers are required in buildings where the top floor is more than 50 metres above fire service access level, as fire brigade equipment cannot deliver sufficient pressure beyond this height.

Our systems are designed in accordance with BS 9990 and include:

  • A dedicated storage tank (typically 67.5m³ or 45m³ with 500 l/min infill)

  • Duty and standby pump sets delivering 750 l/min to the two most remote outlets

  • Pressure-reducing outlet valves at every level, including the ground floor

  • Staged systems where outlet pressure exceeds 20 bar

  • Maintenance valves at 10m intervals for sectional isolation

  • Test and drain lines for flow testing and water recovery

  • Emergency infill for fire brigade use at ground level

Wet risers must undergo commissioning flow tests and annual servicing. During construction, a dry riser should be installed from 11 metres and converted to a wet riser once the building exceeds 50 metres.

 
Book a Free Consultation

Commercial Sprinkler Systems Designed to EN 12845

Commercial sprinkler systems are designed to contain and control fires in commercial and industrial buildings. 

They are installed in accordance with EN 12845, the European standard governing the design, installation, and maintenance of these systems.

Their primary functions are to:

  • Activate sprinkler heads in the affected area

  • Control or extinguish the fire before it spreads

  • Protect life, property, and business continuity

These systems are typically used in:

  • Warehouses

  • Factories

  • Retail centres

  • Office buildings

  • Other commercial and industrial premises

What Does EN 12845 Specify?

EN 12845 provides detailed technical guidance on:

 

  • Hazard classification: Systems are designed based on the type and level of fire risk – Light, Ordinary, or High Hazard.
  • System layout: Includes spacing and positioning of sprinkler heads to ensure effective coverage.
  • Water supplies: Requirements for dedicated water sources, such as storage tanks and pumps, to maintain pressure and flow.
  • Pipework and components: Materials, sizing, and installation standards for reliability and durability.
  • Alarm and monitoring systems: Integration with fire detection and building management systems.
  • Inspection and maintenance: Regular testing and upkeep to ensure systems remain operational over time.

Residential and Domestic Sprinkler Systems designed to BS9251

Sprinkler systems have been in use for over 150 years, originally developed to protect commercial and industrial properties. Over time, they have become a key part of life safety in the residential and domestic market, with the primary goal of saving lives.

A properly designed and installed sprinkler system controls a fire at its source, allowing time for the safe evacuation of occupants.

We install residential and domestic sprinkler systems in a wide range of buildings, including:

  • Individual houses and domestic dwellings

  • Low-rise and high-rise apartment blocks

  • Care homes

  • Houses in multiple occupation (HMOs)

  • Student accommodation

  • Bed and breakfasts

  • Hostels

Retro Sprinkler Systems

Residential and domestic sprinkler systems can be installed retrospectively, without the need for major intrusive works such as opening walls or ceilings. This is achieved by housing the pipework within preformed boxing, with sidewall sprinkler heads fitted flush to the face of the boxing.

While not required in older buildings when first constructed, many building owners, landlords, housing associations, and stakeholders have chosen to install sprinklers retrospectively to enhance fire protection.

This proactive approach to fire safety significantly reduces the risk to life and property in the event of a fire.

We are proud to serve nationwide

Company Registration Number: 15175830
Vat Number: 451 5623 05

ReCom Fire Protection specialise in the design, supply, installation, commissioning, servicing, and maintenance of residential, domestic and commercial sprinkler systems nationwide.

ReCom Fire Protection Copywrite 2025 ©

Website Designed by Brogan Daisy Digital