Case Studies

ReCom Fire Protection has delivered sprinkler solutions for a wide variety of sectors and building types across the UK.

Our case studies highlight projects ranging from small-scale installations to complex large-scale systems, covering every stage from design and installation to commissioning and ongoing maintenance. Each example demonstrates our commitment to safety, compliance and delivering reliable systems with minimal disruption.

Latest Case Studies

Recom fire protection westfield london
Recom fire protection westfield london (1)

Westfield, London

Client: NSBS

Location: Westfield Shepherds Bush

Scope of Work:  Design & Installation of the sprinkler system alterations to provide a compliant layout in line with the new GA plans and RCP’s

Programme: 3nr weeks.

Queen Elizabeth Hospital

Client: Sotham Engineering

Location: Queen Elizabeth Hospital, Kings Lynn

Scope of Work: Design, Supply, Installation of new site wide dry riser system in accordance with BS9990 2015 consisting of a new ring main to the existing hospital connecting into 2no existing dry risers and introducing 15 new dry risers consisting of 33 new outlets.

Programme: 16nr weeks.

Queen Elizabeth Hospital Case Study
Queen Elizabeth Hospital Case Study (2)
Queen Elizabeth Hospital Case Study (1)
Kane Group Case Study (3)
Kane Group Case Study (2)
Kane Group Case Study (4)
Kane Group Case Study (5)

Hurlingham

Client: Kane Group

Location: Hurlingham Waterfront

Scope of Work: Design, Supply, Installation & Commissioning of a Category 4 residential sprinkler system in accordance with BS9251:2021 consisting of 269 apartments split across 2 blocks. The sprinkler system utilises the BCWS pump and tank with a dedicated primary valve group and dedicated sprinkler riser feeding each level.

Programme: 52nr weeks.

Anytime Fitness

Client: Anytime Fitness

Location: Seven Sisters Road, London

Scope of Work:  Design & Installation of the sprinkler system extension to protect the gym and to provide a compliant layout in line with the new GA plans and RCP’s.

Programme: 4nr weeks.

Anytime Fitness Case Study (7)
Anytime Fitness Case Study
Pj Plumbing Case Study (3)
Pj Plumbing Case Study
Pj Plumbing Case Study (2)

Swaffham SEN School

Client: PJ Plumbing

Location: Lynn Road, Swaffham, PE37 7BB.

Scope of Work: Design, Supply, Installation & Commissioning of an OH1 Commercial sprinkler system in accordance with BSEN12845 & TB221 consisting of a 3D design and Installation of an OH1 commercial sprinkler system to protect the entire school building across 3 levels. The water supply is located externally in a purpose built enclosure and fed via an underground main.

Programme: 38nr weeks.

We are proud to serve nationwide